Weihai Kunke Flow Instrument Co.,Ltd.

MESSAHE     |     CONTACT

18 years Focus on flow meter manufacturers

100,000 units of manufacturing experience, high-tech enterprise, stock code: 301657

Mailbox:
+kkad8@whliuliangji.com

Popular keywords: Vortex flowmeter Electromagnetic flowmeter Gas turbine flowmeter Gas waist wheel flowmeter

Search

NEWS

News

The reason why the meter head of the precession vortex flowmeter is not showing has nothing to do with the extreme high temperature

2022-07-15 16:42:54

Click:

  You must know that the continuous high temperature weather has occupied the hot search list for several days, but for us watchers, this content has nothing to do with it, but the editor's knowledge wants to say that the weather is hot, everyone pay attention to heatstroke prevention, avoid heat stroke. Now let's get down to business, what are your thoughts on the direction and position of the meter head of the precession vortex flowmeter? It is necessary to know that the reason why the meter head of the precession vortex flowmeter does not show is actually related to the following contents.

  Precession vortex flowmeters are widely used in daily life. When you introduce this product, you usually introduce the characteristics and performance of the flowmeter, but the introduction of the meter head of the flowmeter is relatively small. Then we will introduce the performance of the problem with the head of the meter below.

  The meter head of the precession vortex flowmeter has no performance: the liquid crystal panel of the flowmeter is damaged. Change the flow meter LCD panel; the power wiring is wrong or disconnected. Find and rewire; flowmeter does not have 24V power or battery power. Provide 24V power supply to the flowmeter or replace the flowmeter battery; the flowmeter motherboard is damaged. Replace the flowmeter motherboard.

  The meter head of the precession vortex flowmeter shows that the instantaneous flow and pressure are normal, but the temperature performance does not match the working site temperature. The temperature indication value is lower than or exceeds the actual temperature on site. After changing the sensor, it is still abnormal, indicating that the temperature and pressure circuit is damaged. The temperature and pressure circuit can be changed; the temperature indication value is "-75C" or "100", indicating that the temperature sensor is damaged. Interchangeable sensor.

  The above introduces the aspects that can be checked if there is a problem with the meter head of the precession vortex flowmeter when it is used. If you have any doubts about the above content, or have suggestions that need to be supplemented, the editor welcomes you to discuss with the editor at any time, let us learn more about flowmeters, and let us know more about flowmeters in the ocean of flowmeters. Ride the wind and waves and discover more new fields in the flow meter industry.

Author: Weihai Kunke Flow Instrument Co.,Ltd.
0
The reason why the meter head of the precession vortex flowmeter is not showing has nothing to do with the extreme high temperature
You must know that the continuous high temperature weather has occupied the hot
Long by picture save/share

KUNKEANDAO

Home                     
Solution  

Vortex Flowmeter        
Technical Support

Electromagnetic Flowmeter 
About

Liquid flowmeter           
Contact


CONTACT

TEl:+8613863136693

ADD:Building 6, Electronic Information and Intelligent Manufacturing Industrial Park,369 Shuangdao Road, Shuangdaowan Science and Technology City, Weihai City,Shandong Province,China.

E-mail:kkad8@whliuliangji.com

FAX:0631-5669277

图片展示

KUNKEANDAO

Copyright©2021 Weihai Kunke Flow Instrument Co.,Ltd.    鲁ICP备17042927号-6

版权所有@威海坤科流量仪表股份有限公司  鲁ICP备17042927号-2

Service Center

Please choose online customer service to communicate

Contacts
热线电话
+8613863136693
E-mail地址
kkad8@whliuliangji.com
Scan a QR Code
Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.